Hyper Light

Disinfection Robot

Hyper Light Disinfection Robot generates high output UVC dosage delivered by the amalgam lamps and protective reflector technology to kill 99.99~99.9999% pathogens on high-touch surfaces in 5 to 15 minutes. 

By effective and efficient disinfection, Hyper Light can improve environmental hygiene and reduce healthcare-associated infection (HAI) in the healthcare facilities to provide safer environment for patients and healthcare workers and achieve better quality of care.

Hyper Light Disinfection Robot P Series
1

Effective Disinfection

Clinically proven germicidal efficacy of up to 99.99%, effective against viruses, bacteria, fungi, and C. difficile spores, including coronavirus, H1N1, S. aureus, E. coli, and C. albicans.

Hyper Light Disinfection Robot P Series
Hyper Light Disinfection Robot P Series
2

Patented Reflective Cover

Enhances UVC performance by evenly reflecting over three times the UVC dosage, enabling rapid and effective inhibition of microorganism growth. The cover also protects the lamps during standby mode and helps prevent damage from accidental impact.

 

3

Effective UVC Amalgam Disinfection

Powered by a long-life, ozone-free UVC amalgam lamp with low thermal sensitivity, delivering continuous high-dosage UVC output without toxic residue or environmental impact. Achieves fast and effective surface disinfection within a 3-meter radius in just 5–15 minutes, with a 12,000-hour lamp life capable of covering over 48,000 patient rooms, significantly reducing maintenance costs.

Hyper Light Disinfection Robot P Series

 

Hyper Light Disinfection Robot P Series
4

Dual Human Safety Protection System

Equipped with all-around multi-motion sensors and a tablet vibration sensor to detect accidental entry during disinfection. The system automatically terminates operation to minimize UVC exposure and ensure user safety.

 

5

Tablet-Based Remote Control & Record Management

Supports wireless tablet operation for disinfection, with downloadable and retrievable data records to verify and confirm completion of each disinfection procedure.

Hyper Light Disinfection Robot P Series

 

Hyper Light Disinfection Robot P Series
6

Easy Validation – 
FastCheck

FastCheck provides quick visual confirmation of disinfection performance. Simply place it in the disinfection area—the indicator changes from yellow to green, verifying 99.99% germicidal efficacy.

 

7

High Maneuverability

With four 4 inch omnidirectional wheels, Hyper Light can be pushed to any location in hospitals. Only 3.2kg of force is needed for movement, conforming to AORN standards.

Hyper Light Disinfection Robot P Series

 

Hyper Light Disinfection Robot P Series
8

LED Status Indication

Operation status is easily determined from long distance by LED indicator.

 

 

 

OPERATION METHOD

Hyper Light can be multi-placement for room disinfection to optimize the UVC exposure on high-touch surfaces and overcome the shadow issue. The typical operation time of each position is 5 minutes, and it can be adjusted according to user’s needs.

  • 2-3 position ( 1.Left side of bed 2.Right side of bed 3.Toilet )
  • 5 mins/position
(General ward, 21 m2)
Hyper Light Disinfection Robot P Series

 

 

CLINICAL DISINFECTION REPORT

Hyper Light has been clinical proven by hospitals and third-party international certification labs to eradicate 99.99% to 99.9999% of pathogens within 2.7 to 3 meters radius in 5 to 15 minutes.

Hyper Light Germicidal Efficacy

 
PATHOGENS MDRO (Unit: CFU)
MRSA
MDRAB
MDRPA
VRE
BEFORE TREATMENTEXPOSED 5 MINSEXPOSED 10 MINSEXPOSED 15 MINS
1.0 × 1094.8 × 1032.6 × 1038.0 × 102
1.1 × 1084.2 × 1034.0 × 102<1
8.2 × 1083.0 × 1036.0 × 1022.0 × 102
2.8 × 1078.0 × 1056.0 × 1022.0 × 102
 
PATHOGENS Viruses (Unit: PFU)
Coronavirus 229E
H1N1
Influenza B
Enterovirus 71
BEFORE TREATMENTEXPOSED 5 MINSEXPOSED 10 MINSEXPOSED 15 MINS
6.5 × 103<1<1<1
1.0 × 1085.0 × 1026.0 × 10<1
1.0 × 1084.0 × 1021.5 × 10<1
1.0 × 1084.0 × 1035.0 × 1022
 
PATHOGENS Bacteria (Unit: CFU)
S. aureus 
E. faecalis 
E. coli 
K. pneumoniae 
A. baumannii 
P. aeruginosa 
M. abscessus 
BEFORE TREATMENTEXPOSED 5 MINSEXPOSED 10 MINSEXPOSED 15 MINS
3.3 × 106 1.1 × 102 2.4 × 10 < 1 
8.4 × 106 1.2 × 105 2.8 × 102 < 1 
5.8 × 106 1.8 × 102 <1 < 1 
8.5 × 106 2.2 × 10 <1 < 1 
1.1 × 107 4.0 × 103 2.2 × 10 < 1 
3.4 × 106 <1 <1 < 1 
9.2 × 108 2.0 × 105 1.6 × 104 4.0 × 102 
 
PATHOGENS Bacterial Spores (Unit: CFU)
C. difficile 
B. atrophaeus
BEFORE TREATMENTEXPOSED 5 MINSEXPOSED 10 MINSEEXPOSED 15 MINS
2.9 × 106 5<1 < 1 
3.2 × 1063--
 
PATHOGENS Fungus (Unit: CFU)
A. brasiliensis 
C. albicans
BEFORE TREATMENTEXPOSED 5 MINSEXPOSED 10 MINSEXPOSED 15 MINS
5.3 × 106 5.3 × 103 <1 < 1 
1.2 × 1067--

Hyper Light Room Disinfection Efficacy (Area: 21 m2, Unit: CFU)

 
SITE OF SAMPLING
Left Bedrail 
Right Bedrail 
Top of Bedside Table 
Telephone 
Door Knob of Refrigerator 
Switch 1 
Switch 2 
Before Treatment After Treatment Reduction (%) 
200100%
00N/A 
500100%
2800100%
1700100%
1200100%
00N/A 
Hyper Light Disinfection Robot P Series
National Taiwan University Hospital, Taiwan

Effectiveness of an ultraviolet-C disinfection system for reduction of healthcareassociated pathogens

Hyper Light Disinfection Robot P Series
Pisa University, Italy

Disinfezione delle aree critiche del setting assistenziale, per il contrasto della diffusione delle infezioni da germi multi-farmaco resistenti

Hyper Light Disinfection Robot P Series
Chang Gung University, Taiwan

Hyper Light Disinfection Robot Antiviral Effects on Coronavirus

Hyper Light Disinfection Robot P Series
Taichung Veterans General Hospital, Taiwan

Evaluating the effectiveness of an ultraviolet-C device for terminal room disinfection

Hyper Light Disinfection Robot P Series
Chang Gung University, Taiwan

Antiviral mechanism study for 254UVC Disinfction Robot System

Hyper Light Disinfection Robot P Series
SGS Taiwan

Antimicrobial Effectiveness Testing

 

 