Effectively kill pathogens up to 99.9999% in 5 to 15 minutes by high output 254 nm UVC light to reduce healthcare-associated infection and improve hospital environmental hygiene.
Hyper Light Disinfection Robot generates high output UVC dosage delivered by the amalgam lamps and protective reflector technology to kill 99.99~99.9999% pathogens on high-touch surfaces in 5 to 15 minutes.
By effective and efficient disinfection, Hyper Light can improve environmental hygiene and reduce healthcare-associated infection (HAI) in the healthcare facilities to provide safer environment for patients and healthcare workers and achieve better quality of care.
The patented protective reflector technology applied in Hyper Light reflects UVC energy up to 90% and rotates during operation. By increasing UVC dosage, disinfection range and optimizing the distribution of UVC energy, Hyper Light can enhance the germicidal efficacy on high-touch surfaces and improve the environmental hygiene. During standby mode, it will also cover the lamps to avoid any lamp damage from accidentally impact.
The amalgam lamps offer high power, low pressure and ozone-free features; these special properties allow the lamps to operate at high temperature, produce no ozone gas, leave no toxic residues, generate low thermo-sensitivity and possess long lifetime compared with conventional low-pressure mercury lamps.
All-around multi-motion sensors and tablet vibration sensor are equipped to prevent potential injuries from accidental entry during the disinfection process. Hyper Light will automatically terminate the procedure to minimize UVC exposure and ensure human safety.
The intuitive tablet control system provides user-friendly interface for wireless operation and real time documentation for all your validation and verification processes. The disinfection data can be also exported for future research.
FastCheck allows for quick visualization of disinfection performance. Simply place the FastCheck on the disinfection area, the color will change from yellow to green which indicating 99.99% germicidal efficacy of the disinfection process.
With four 4 inch omnidirectional wheels, Hyper Light can be pushed to any location in hospitals. Only 3.2kg of force is needed for movement, conforming to AORN standards.
Operation status is easily determined from long distance by LED indicator.
Hyper Light can be multi-placement for room disinfection to optimize the UVC exposure on high-touch surfaces and overcome the shadow issue. The typical operation time of each position is 5 minutes, and it can be adjusted according to user’s needs.
Hyper Light has been clinical proven by hospitals and third-party international certification labs to eradicate 99.99% to 99.9999% of pathogens within 2.7 to 3 meters radius in 5 to 15 minutes.
PATHOGENS MDRO (Unit: CFU) |
---|
MRSA |
MDRAB |
MDRPA |
VRE |
BEFORE TREATMENT | EXPOSED 5 MINS | EXPOSED 10 MINS | EEXPOSED 15 MINS |
---|---|---|---|
1.0 × 109 | 4.8 × 103 | 2.6 × 103 | 8.0 × 102 |
1.1 × 108 | 4.2 × 103 | 4.0 × 102 | <1 |
8.2 × 108 | 3.0 × 103 | 6.0 × 102 | 2.0 × 102 |
2.8 × 107 | 8.0 × 105 | 6.0 × 102 | 2.0 × 102 |
PATHOGENS Viruses (Unit: PFU) |
---|
Coronavirus 229E |
H1N1 |
Influenza B |
Enterovirus 71 |
BEFORE TREATMENT | EXPOSED 5 MINS | EXPOSED 10 MINS | EEXPOSED 15 MINS |
---|---|---|---|
6.5 × 103 | <1 | <1 | <1 |
1.0 × 108 | 5.0 × 102 | 6.0 × 10 | <1 |
1.0 × 108 | 4.0 × 102 | 1.5 × 10 | <1 |
1.0 × 108 | 4.0 × 103 | 5.0 × 102 | 2 |
PATHOGENS Bacteria (Unit: CFU) |
---|
S. aureus |
E. faecalis |
E. coli |
K. pneumoniae |
A. baumannii |
P. aeruginosa |
M. abscessus |
BEFORE TREATMENT | EXPOSED 5 MINS | EXPOSED 10 MINS | EEXPOSED 15 MINS |
---|---|---|---|
3.3 × 106 | 1.1 × 102 | 2.4 × 10 | < 1 |
8.4 × 106 | 1.2 × 105 | 2.8 × 102 | < 1 |
5.8 × 106 | 1.8 × 102 | <1 | < 1 |
8.5 × 106 | 2.2 × 10 | <1 | < 1 |
1.1 × 107 | 4.0 × 103 | 2.2 × 10 | < 1 |
3.4 × 106 | <1 | <1 | < 1 |
9.2 × 108 | 2.0 × 105 | 1.6 × 104 | 4.0 × 102 |
PATHOGENS Bacterial Spores (Unit: CFU) |
---|
C. difficile |
B. atrophaeus |
BEFORE TREATMENT | EXPOSED 5 MINS | EXPOSED 10 MINS | EEXPOSED 15 MINS |
---|---|---|---|
2.9 × 106 | 5 | <1 | < 1 |
3.2 × 106 | 3 | - | - |
PATHOGENS Fungus (Unit: CFU) |
---|
A. brasiliensis |
C. albicans |
BEFORE TREATMENT | EXPOSED 5 MINS | EXPOSED 10 MINS | EEXPOSED 15 MINS |
---|---|---|---|
5.3 × 106 | 5.3 × 103 | <1 | < 1 |
1.2 × 106 | 7 | - | - |
SITE OF SAMPLING |
---|
Left Bedrail |
Right Bedrail |
Top of Bedside Table |
Telephone |
Door Knob of Refrigerator |
Switch 1 |
Switch 2 |
Before Treatment | After Treatment | Reduction (%) |
---|---|---|
20 | 0 | 100% |
0 | 0 | N/A |
50 | 0 | 100% |
280 | 0 | 100% |
170 | 0 | 100% |
120 | 0 | 100% |
0 | 0 | N/A |
Effectiveness of an ultraviolet-C disinfection system for reduction of healthcareassociated pathogens
Disinfezione delle aree critiche del setting assistenziale, per il contrasto della diffusione delle infezioni da germi multi-farmaco resistenti
Hyper Light Disinfection Robot Antiviral Effects on Coronavirus
Evaluating the effectiveness of an ultraviolet-C device for terminal room disinfection
Antiviral mechanism study for 254UVC Disinfction Robot System
Antimicrobial Effectiveness Testing